INSTALLATION - Continued
49.
Connect wire (Figure 16, Item 3) to air dryer heater wire (Figure 16, Item 2).
50.
Install tiedown straps (Figure 16, Item 1) on wire (Figure 16, Item 3).
51.
Install clamp (Figure 16, Item 4) on firewall (Figure 16, Item 9) with washer (Figure 16, Item 19) and screw
(Figure 16, Item 18).
52.
Install ground strap (Figure 16, Item 8), bracket (Figure 16, Item 10), and clamp (Figure 16, Item 14) on firewall
(Figure 16, Item 9) with washer (Figure 16, Item 15) and screw (Figure 16, Item 16).
53.
Install ground wire (Figure 16, Item 5) on flywheel housing (Figure 16, Item 17) with washer
(Figure
16,
Item
6) and screw (Figure 16, Item 7).
54.
Connect two wires (Figure 16, Item 12) to connectors (Figure 16, Items 11 and 13).
55.
Connect connector (Figure 16, Item 21) to fuel pressure transducer (Figure 16, Item 22).
56.
Connect connector (Figure 16, Item 20) to throttle control solenoid (Figure 16, Item 23).