REMOVAL
WARNING
•
Remove all jewelry. If jewelry or disconnected battery ground cable contacts positive
battery terminal, a direct short will result. Failure to comply may result in damage to
equipment, injury, or death to personnel.
•
Do not remove slave receptacle before disconnecting battery ground cables. If energized
battery cable contacts cab, a direct short will result. Failure to comply may result in
damage to equipment, injury, or death to personnel.
1.
Remove four nuts (Figure 1, Item 10), screws (Figure 1, Item 12), rope (Figure 1, Item 11), and cover
(Figure
1, Item 13) from cab (Figure 1, Item 6).
NOTE
Insulating hose remains inside cab.
2.
Pull slave receptacle (Figure 1, Item 14) until battery cables (Figure 1, Items 3 and 9) are exposed.
3.
Remove two screws (Figure 1, Item 1), lockwashers (Figure 1, Item 2), and battery cables
(Figure
1,
Items
3
and
9) from slave receptacle (Figure 1, Item 14). Discard lockwashers.
4.
Remove insulator (Figure 1, Item 5) and gasket (Figure 1, Item 4) from slave receptacle (Figure 1, Item 14).
5.
Pull cables (Figure 1, Items 3 and 9) clear of insulating hose (Figure 1, Item 7) and remove from battery box
(Figure 1, Item 8).
TM 9-2320-272-23-3
0353
0353-2