TERMINAL-TYPE CABLE CONNECTOR
WARNING
Do not wear jewelry when repairing harnesses. Failure to comply may result in damage to
equipment, injury, or death to personnel.
NOTE
If a wiring harness is damaged beyond repair, notify unit maintenance for replacement.
1.
Strip cable insulation (Figure 1, Item 1) from cable (Figure 1, Item 2) to equal depth of terminal well
(Figure
1,
Item
4).
2.
Slide insulator (Figure 1, Item 3) over cable (Figure 1, Item 2).
3.
Insert cable (Figure 1, Item 2) into terminal well (Figure 1, Item 4) and crimp.
4.
Slide insulator (Figure 1, Item 3) over crimped end of terminal (Figure 1, Item 5).
1
2
3
4
5
M8047DAA
Figure 1.
Terminal-Type Cable Connector.
END OF TASK
MALE CABLE CONNECTOR
1.
Strip cable insulation (Figure 2, Item 1) from cable (Figure 2, Item 2) equal to depth of ferrule well
(Figure
2,
Item
5).
2.
Slide shell (Figure 2, Item 3) over cable (Figure 2, Item 2).
3.
Insert cable (Figure 2, Item 2) into ferrule well (Figure 2, Item 5) and crimp.
4.
Place C-washer (Figure 2, Item 4) over crimped junction at terminal (Figure 2, Item 6).
5.
Slide shell (Figure 2, Item 3) over C-washer (Figure 2, Item 4) and terminal (Figure 2, Item 6).
TM 9-2320-272-23-3
0352
0352-2