INSTALLATION
1.
Install mounting bracket (Figure 2, Item 11) on cab protector (Figure 2, Item 6) with four washers
(Figure
2,
Item
9), screws (Figure 2, Item 10), washers (Figure 2, Item 4), and locknuts (Figure 2, Item 5).
2.
Install mounting plate (Figure 2, Item 1) on support tube (Figure 2, Item 2).
3.
Install support tube (Figure 2, Item 2) on mounting bracket (Figure 2, Item 11) with wing screw
(Figure
2,
Item
3).
4.
Install two cable leads (Figure 2, Item 8) on support tube (Figure 2, Item 2) and mounting bracket
(Figure
2,
Item
11).
5.
Connect two cable leads (Figure 2, Item 8) to harness leads (Figure 2, Item 7).
3
4
5
M9940DAA
1
2
6
7
8
9
10
11
Figure 2.
Convoy Warning Light Mount Installation.
END OF TASK