TM9-2320-273-34
Do not use a metal hammer in step (3),
Use a rubber of fiber mallet so that the
end of the shaft will not be damaged.
(3) Remove the top input shaft assembly (3, fig. 8-5) and gasket (1) from the rear side of the
case by tapping the shaft from the front side with a mallet, then remove two capscrews (4) and plate (5).
Do not remove guide pin unless bent or damaged.
LEG
1.
2.
3.
4.
5.
END:
GASKET
CASE
INPUT SHAFT
CAPSCREW (2)
PLATE
Figure 8-5. Top Input Shaft Assembly RemovaL
TA 074198
8-5
CAUTIO N