TM 9-2320-328-13&P-1
0089-38
DRAFT
0089
Change 1
.
HWT1949
.
Step 54.
Remove diode block from cab power distribution block (WP 0243).
Install a jumperwire
between diode block terminals wire 1592 (gray) and wire 1609 (gray).
With rear
compartment doors open, check for continuity between wire 1592 (gray) cab instrument
panel wire harness connector, terminal 10 and a known good ground.
.
If there is continuity, replace diode block (WP 0243).
.
Step 55.
Remove jumperwire used in previous step. With a test lead set, check for continuity
across cab power distribution wire harness wire 1592 (gray) between cab instrument
panel wire harness cab power distribution wire harness connector, terminal 10 and
diode block connector terminal.
.
If there is no continuity, repair wire 1592 in cab power distribution wire
harness if repairable (TM 9-2320-325-14&P), or replace cab power
distribution wire harness and block (WP 0280).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION