TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 1034 of 1318

TM 9-2320-328-13&P-1
0090-2
DRAFT
0090
HWT0387
Step 1.
Push battery disconnect switch to on position (WP 0007).
If system air pressure is
below 85 psi (586 kPa), start engine and allow system air pressure to build to at least 85
psi (586 kPa) (TM 9-2320-422-10).
Then shut off engine (TM 9-2320-422-10).
Open
pump house panel K (WP 0339).
While an assistant puts pump operator’s panel FOAM
FLUSH switch to ON position (WP 0004), check if foam flush valve operates to open
position.
If foam flush valve does not operate to open position, troubleshoot Foam
System Cannot Be Flushed (WP 0061).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top