HWT0693
Step 4.
Disconnect jumperwire 2768 (white) from FOAM SYSTEM indicator from both terminal
connectors.
Check for continuity across jumperwire 2768 (white) from terminal to
terminal.
a.
If there is continuity, replace FOAM SYSTEM indicator (WP 0198).
b.
If there is no continuity, repair or replace jumperwire 2768 (white)
(TM 9-2320-325-14&P).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION