TM 9-2320-328-13&P-1
0090-5/(6 blank)
DRAFT
0090
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-422-10)
END OF TASK
END OF WORK PACKAGE
HWT0689
Step 4.
Push battery disconnect switch to on position (WP 0007).
Check for 22 to 28 VDC
between pump operator’s panel wire harness wire 2849 (yellow) from pump operator’s
panel FOAM FLUSH indicator to a known good ground.
a.
If 22 to 28 VDC are present, replace pump operator’s panel FOAM
FLUSH indicator (WP 0213).
b.
If 22 to 28 VDC are not present, repair wire 2849 in pump operator’s
panel wire harness if repairable (TM 9-2320-325-14&P), or replace
pump operator’s panel wire harness (WP 0303).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top