HWT0758
.
Step 10.
Put STEP LIGHTS switch to off position (WP 0004).
Turn Service Drive Lights
Off (TM 9-2320-422-10).
Pull battery disconnect switch to off position (WP 0007).
Disconnect cab instrument panel wire harness step lights switch connector.
Check for
continuity across STEP LIGHTS switch, from terminal 5 to terminal 6, when switch is
put to on position.
.
If there is no continuity, replace STEP LIGHTS switch (WP 0199).
.