TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 216 of 1318

TM 9-2320-328-13&P-1
0029-6
DRAFT
0029
Change 1
26. When water runs clear, push NO. 2 PASSENGER SIDE DISCHARGE valve control CLOSE button (21) until
red indicator light (22) illuminates.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
27. Open water PUMP DRAIN valve (23).
When water runs clear, close water PUMP DRAIN valve (23).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
28. Put FOAM FLUSH switch (2) to OFF position.
Indicator light (3) will go out.
29. Put HIGH IDLE switch (24) to OFF position.
Indicator light (25) will illuminate.
30. Put PUMP PTO switch (26) to off position.
Indicator light (27) will go out.
HWT0303
HWT2727A


Back to Top