TM 9-2320-328-13&P-1
0057-7
DRAFT
0057
Change 1
.
HWT0349
.
Step 10.
Close foam tank drain valve and install cap (WP 0022).
Close foam system service
valve (WP 0004).
Remove hose reel (WP 0247).
Position suitable drain pan under
foam system strainer.
Remove plug and strainer screen from foam system strainer
(WP 0183).
Check if foam system strainer screen is free from clogs and damage.
.
If foam system strainer is clogged or damaged, clean or replace strainer
screen (WP 0183).
.
Step 11.
Install foam system strainer screen and plug (WP 0183).
Remove foam system inlet
check valve (WP 0180).
Check if foam system inlet check valve is free from blockage
and damage.
.
If foam system inlet check valve is blocked or damaged, remove blockage or
replace foam system inlet check valve (WP 0180).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION