NOTE
Ensure system air pressure is at least 85 psi (586 kPa) during this procedure.
System air
pressure is required to activate valves.
Do not engage PUMP PTO during this procedure, except when performing complete
system checks.
Valve operations can be checked without water pump operation.
Valve operations can be checked by observing valve shaft rotation.
.
Step 24.
Release pump operator’s panel FOAM SYSTEM switch (WP 0004).
While an assistant
puts cab FOAM SYSTEM switch to off position (WP 0004), check if foam system shutoff
valve operates to closed position.
.
If foam system shutoff valve does not operate to closed position, go to
Step 28.
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION