TM 9-2320-328-13&P-1
0057-8
DRAFT
0057
Change 1
.
HWT0352
.
Step 12.
Install foam system inlet check valve (WP 0180).
Remove plug and strainer screen
from eductor strainer (WP 0183).
Check eductor strainer screen for clogs and damage.
.
If eductor strainer is clogged or damaged, clean or replace strainer screen
(WP 0183).
.
Step 13.
Install eductor strainer screen and plug (WP 0183).
Open foam system service valve
(WP 0004).
Start engine (TM 9-2320-422-10).
Set up system to pump from onboard
water tank (WP 0019).
Put cab or pump operator’s panel FOAM SYSTEM switch to ON
position (WP 0004).
Operate bumper turret (WP 0027), under truck nozzles
(WP 0028), or hose reel with manual metering valve (WP 0024).
Check if foam is
delivered when system is operated.
Flush foam system (WP 0022).
.
a.
If foam is delivered, problem has been corrected.
.
b.
If foam is not delivered, replace eductor (WP 0177).
.
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top