Step 19.
Pull battery disconnect switch to off position (WP 0007).
Disconnect pump house wire
harness eductor control valve connector.
With a test lead set, check for continuity
across wire 4054 (yellow) from pump house wire harness diode pack connector,
terminal D to eductor control valve connector, terminal 1.
.
a.
If there is continuity, replace diode pack (WP 0269).
.
b.
If there is no continuity, repair wire 4054 in pump house wire harness if
repairable (TM 9-2320-325-14&P), or replace pump house wire
harness (WP 0302).
.
Step 20.
Put FOAM FLUSH switch to OFF position (WP 0004).
Check if air line from air control
valve manifold to eductor valve is free from kinks and damage.
.
If air line is kinked or damaged, replace damaged air line (WP 0374).
.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION