TM 9-2320-328-13&P-1
0064-13
DRAFT
0064
HWT2958
Step 15.
Connect pump house wire harness pump house power distribution wire harness
connector DP2.
Disconnect main wire harness pump house wire harness 4-pin
connector.
With a test lead set, check for continuity across wire 2330 from main wire
harness pump house wire harness 4-pin connector, terminal 3 to pump operator’s panel
wire harness WATER LEVEL gauge connector, terminal 5.
If there is continuity, repair wire 2330 in pump house wire harness if
repairable (TM 9-2320-325-14&P), or replace pump house wire
harness (WP 0302).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION