TM 9-2320-328-13&P-1
0064-17
DRAFT
0064
HWT3024
Step 20.
Disconnect main wire harness pump operator’s panel 27-pin wire harness connector.
With a test lead set, check for continuity across wire 2315 (yellow) from main wire
harness pump operator’s panel 27-pin wire harness connector, terminal 10 to pump
house wire harness pump house power distribution wire harness connector DP2,
terminal G.
If there is continuity, repair wire 2315 in pump operator’s panel wire harness
if repairable (TM 9-2320-325-14&P), or replace pump operator’s panel wire
harness (WP 0303).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION