NOTE
•
To locate correct datalink cable connector in cab, follow green banded datalink cable from
main wire harness cab pressure governor control connector to first Y connector in series.
•
To locate correct datalink cable connector in pump operator’s panel, follow green banded
datalink cable from pump operator’s panel pressure governor control connector to first Y
connector in series.
..
Step 50.
Remove cab instrument panel E (WP 0339).
Disconnect main wire harness datalink
cable connector from CAN datalink Y connector.
Disconnect pump operator’s panel
wire harness datalink cable connector from CAN datalink Y connector.
With a test lead
set, check for continuity across CAN datalink cable CAN Shield wire (bare) from CAN
datalink cable Y connector (that was disconnected from main wire harness), terminal C
to CAN datalink cable Y connector (that was disconnected from pump operator’s panel
wire harness), terminal C.
..
If there is no continuity, replace CAN datalink wire harness
(TM 9-2320-325-14&P).
..
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION