WARNING
..
ICON 3
..
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
..
Step 60.
Turn engine off (TM 9-2320-422-10).
Pull battery disconnect switch to off position
(WP 0007).
Remove pump house panel K (WP 0339).
Disconnect pump house wire
harness discharge pressure transducer connector.
Disconnect pump house wire
harness intake pressure transducer connector.
Swap pressure transducer connectors
on pressure transducers.
Push battery disconnect switch to on position (WP 0007).
Scroll pressure governor through diagnostic screen and caution faults (WP 0017).
Check if caution fault has changed to Intake Pressure Transducer Failure with an Open
Circuit (WP 0017).
..
If caution fault has changed to Intake Pressure Transducer Failure with an
Open Circuit, replace discharge pressure transducer (WP 0265).
..
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION