TM 9-2320-328-13&P-1
0072-62
DRAFT
0072
Change 1
..
HWT2649
..
Step 72.
Turn ENGINE switch to OFF position (TM 9-2320-422-10).
Pull battery disconnect
switch to off position (WP 0007).
Remove pump house panel K (WP 0339).
Disconnect
pump house wire harness intake vacuum transducer connector.
Push battery
disconnect switch to on position (WP 0007).
Check if pressure governor control
displays caution fault, Intake Vacuum Transducer Failure with an Open Circuit.
..
If pressure governor control displays caution fault, Intake Vacuum
Transducer Failure with an Open Circuit, replace intake vacuum transducer
(WP 0265).
..
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION