TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 729 of 1318

TM 9-2320-328-13&P-1
0072-65
DRAFT
0072
Change 1
..
HWT2637
..
Step 77.
Turn engine off (TM 9-2320-422-10).
Pull battery disconnect switch to off position
(WP 0007).
Remove pump house panel K (WP 0339).
Disconnect pump house wire
harness discharge pressure transducer connector.
Disconnect pump house wire
harness intake pressure transducer connector.
Swap pump house wire harness
pressure transducer connectors on pressure transducers.
Push battery disconnect
switch to on position (WP 0007).
Scroll pressure governor through diagnostic screen
and caution faults (WP 0017).
Check if caution fault has changed to Discharge
Pressure Transducer Failure with an Open Circuit (WP 0017).
..
If caution fault has changed to Discharge Pressure Transducer Failure with
an Open Circuit, replace Intake pressure transducer (WP 0265).
..
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION