TM 9-2320-328-13&P-1
0072-68
DRAFT
0072
Change 1
..
HWT2670
..
Step 81.
Turn engine off (TM 9-2320-422-10).
Pull battery disconnect switch to off position
(WP 0007).
Remove pump house panel K (WP 0339).
Disconnect pump house wire
harness intake pressure transducer connector.
Push battery disconnect switch to on
position (WP 0007).
Check if pressure governor control displays caution fault, Intake
Pressure Transducer Failure with an Open Circuit (WP 0017).
..
If pressure governor control displays caution fault, Intake Pressure
Transducer Failure with an Open Circuit, replace intake pressure transducer
(WP 0265).
..
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION