TM 9-2320-328-13&P-1
0072-63
DRAFT
0072
Change 1
..
HWT2650
..
Step 73.
Pull battery disconnect switch to off position (WP 0007).
Disconnect pump house wire
harness intake vacuum transducer connector.
Disconnect pump house wire harness
pressure governor ECU J1 connector.
With a test lead set, check for continuity across
pump house wire harness wire 3287 (orange) from pump house wire harness intake
vacuum transducer connector, terminal A to a known good ground.
..
If there is continuity, repair wire 3287 in pump house wire harness if
repairable (TM 9-2320-325-14&P), or replace pump house wire
harness (WP 0302).
..
Step 74.
With a test lead set, check for continuity across pump house wire harness wire 3291
(black) from pump house wire harness intake vacuum transducer connector, terminal B
to a known good ground.
..
If there is continuity, repair wire 3291 in pump house wire harness if
repairable (TM 9-2320-325-14&P), or replace pump house wire
harness (WP 0302).
..
Step 75.
With a test lead set, check for continuity across pump house wire harness wire 3282
(orange) from pump house wire harness discharge pressure transducer connector,
terminal C to a known good ground.
..
If there is continuity, repair wire 3282 in pump house wire harness if
repairable (TM 9-2320-325-14&P), or replace pump house wire
harness (WP 0302).
..
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION