TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 721 of 1318

TM 9-2320-328-13&P-1
0072-57
DRAFT
0072
Change 1
..
HWT2692
..
WARNING
..
ICON 3
..
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
..
Step 64.
Turn engine off (TM 9-2320-422-10).
Pull battery disconnect switch to off position
(WP 0007).
Remove pump house panel K (WP 0339).
Disconnect pump house wire
harness discharge pressure transducer connector.
Push battery disconnect switch to
on position (WP 0007).
Check if pressure governor control displays caution fault,
Discharge Pressure Transducer Failure with an Open Circuit (WP 0017).
..
If pressure governor control displays caution fault, Discharge Pressure
Transducer Failure with an Open Circuit, replace discharge pressure
transducer (WP 0265).
..
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top