TM 9-2320-328-13&P-1
0073-3
DRAFT
0073
HWT0972
Step 5.
Disconnect cab pump control wire harness cab power distribution wire harness
connector.
With a test lead set, check for 22 to 28 VDC between cab power distribution
wire harness wire 2773 (red) at cab power distribution wire harness connector, terminal
E and a known good ground.
a.
If 22 to 28 VDC are present, repair wire 2773 in cab pump control wire
harness if repairable (TM 9-2320-325-14&P), or replace cab pump
control wire harness (WP 0281).
b.
If 22 to 28 VDC are not present, repair wire 2773 in cab power
distribution wire harness if repairable (TM 9-2320-325-14&P), or
replace cab power distribution wire harness (WP 0280).
Step 6.
Put cab PUMP PRIME switch to on position (WP 0004).
Check if primer pump
operates.
If primer pump does not operate when cab PUMP PRIME switch is put to on
position, go to Step 11.
Step 7.
Put cab PUMP PRIME switch to on position (WP 0004).
Check if primer pump draws
water to water pump.
If primer pump operates but does not draw water to water pump, go to
Step 26.
MALFUNCTION
TEST OR INSPECTION