TM 9-2320-328-13&P-1
0073-12
DRAFT
0073
HWT0978A
Step 17.
Pull battery disconnect switch to off position (WP 0007).
Disconnect main wire harness
pump operator’s panel 27-pin wire harness connector.
Disconnect main wire harness
pump house wire harness connector.
With a test lead set, check for continuity across
main wire harness wire 2774 (red) from main wire harness pump house wire harness
connector, terminal 12, to main wire harness pump operator’s panel 27-pin wire harness
connector, terminal 13.
a.
If there is continuity, repair wire 2774 in pump operator’s panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator’s panel wire harness (WP 0303).
b.
If there is no continuity, repair wire 2774 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0292).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION