TM 9-2320-328-13&P-1
0073-21
DRAFT
0073
HWT3097
Step 27.
Stop ENGINE (TM 9-2320-422-10).
Pull battery disconnect switch to off
position (WP 0007).
Remove pump house panel K (WP 0339). Push battery
disconnect switch to on position (WP 0007).
While an assistant puts cab PUMP PRIME
switch to on position (WP 0004), check if primer valve control solenoid is operating.
Operation can be checked by listening for a metallic clicking sound and slight
movement of solenoid.
If primer valve control solenoid does not click and slightly move, go to
Step 34.
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 28.
Check for 22 to 28 VDC between wire 4064 (red) at primer valve control solenoid
terminal and a known good ground.
If 22 to 28 VDC are not present, go to Step 32.
Step 29.
While an assistant puts cab PUMP PRIME switch to on position (WP 0004), check for
22 to 28 VDC between pump house wire harness wire 4065 (red) at primer valve and a
known good ground.
If 22 to 28 VDC are not present, go to Step 31.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION