TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 802 of 1318

TM 9-2320-328-13&P-1
0073-16
DRAFT
0073
HWT0982
Step 21.
Pull battery disconnect switch to off position (WP 0007).
Remove circuit breaker 2 from
cab power distribution block (WP 0242).
Check for continuity across circuit breaker.
a.
If there is no continuity, replace circuit breaker 2 (WP 0242).
b.
If there is continuity, replace cab power distribution wire harness and
block (WP 0299).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top