TM 9-2320-328-13&P-1
0076-10
DRAFT
0076
HWT1753A
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 15.
Release TANK TO PUMP switch (WP 0004).
Remove cab instrument panel A
(WP 0205).
Remove relay 8 (WP 0244).
While an assistant puts cab TANK TO PUMP
switch to close position (WP 0004), check for 22 to 28 VDC between cab power
distribution wire harness wire 2770 (blue) at relay 8 connector, terminal 1 and a known
good ground.
If 22 to 28 VDC are not present, go to Step 17.
Step 16.
Pull battery disconnect switch to off position (WP 0007).
Check for continuity across
cab power distribution wire harness wire 1640 (black) from relay 8 connector, terminal 2
to a known good ground.
a.
If there is continuity, replace relay 8 (WP 0244).
b.
If there is no continuity, replace cab power distribution wire harness
and block (WP 0280).