TM 9-2320-328-13&P-1
0076-11
DRAFT
0076
HWT1168
Step 17.
Pull battery disconnect switch to off position (WP 0007).
Disconnect cab pump control
wire harness cab power distribution wire harness connector.
With a test lead set, check
for continuity across cab pump control wire harness wire 2770 (blue) from cab pump
control wire harness TANK TO PUMP switch connector, terminal 4 to cab pump control
wire harness connector, terminal H.
a.
If there is continuity, repair wire 2770 in cab power distribution wire
harness if repairable
(TM 9-2320-325-14&P), or replace cab power
distribution wire harness and block (WP 0280).
b.
If there is no continuity, repair wire 2770 in cab pump control wire
harness if repairable (TM 9-2320-325-14&P), or replace cab pump
control wire harness (WP 0281).
Step 18.
While an assistant puts cab TANK TO PUMP switch to open position (WP 0004), check
if tank-to-pump valve operates to open position.
If tank-to-pump valve does not operate to open position, go to Step 26.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION