TM-9-2320-328-13-P-1

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 1 OF 3

MARCH 2009

  TM-9-2320-328-13-P-1 - Page 843 of 1318

TM 9-2320-328-13&P-1
0076-5
DRAFT
0076
HWT1163
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle.
Jewelry can catch on equipment and cause serious injury.
Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 9.
Release TANK TO PUMP switch (WP 0004).
Remove cab instrument panel B
(WP 0205).
Disconnect cab pump control wire harness TANK TO PUMP switch
connector.
Check for 22 to 28 VDC between cab pump control wire harness wire 2854
(red) at TANK TO PUMP switch connector, terminal 5 and a known good ground.
If 22 to 28 VDC are not present, repair wire 2854 in cab pump control wire
harness if repairable (TM 9-2320-325-14&P), or replace cab pump control
wire harness (WP 0281).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION