TM 9-2320-328-13&P-1
0076-2
DRAFT
0076
HWT1160
NOTE
•
Ensure system air pressure is at least 85 psi (586 kPa) during this procedure.
System air
pressure is required to activate valves.
•
Do not engage PUMP PTO during this procedure, except when performing complete
system checks.
Valve operations can be checked without water pump operation.
•
Valve operations can be checked by observing valve shaft rotation.
Valves are open when
tabs or yellow paint tabs are aligned with direction of fluid flow.
Step 2.
Put UNDER TRUCK NOZZLES switch to off position (WP 0004). If system air pressure
is below 85 psi (586 kPa), start engine and allow system air pressure to build to at least
85 psi (586 kPa) (TM 9-2320-422-10).
Then shut off engine (TM 9-2320-422-10).
Remove pump house panel K (WP 0339).
While an assistant puts and holds pump
operator’s panel TANK TO PUMP switch to OPEN position (WP 0004), check if tank-to-
pump valve operates to open position.
If tank-to-pump valve does not operate to open position, go to Step 27.
Step 3.
Check if tank-to-pump valve remains in open position, after assistant releases pump
operator’s panel TANK TO PUMP switch (WP 0004).
If tank-to-pump valve does not remain in open position, go to Step 18.
Step 4.
While an assistant puts pump operator’s panel TANK TO PUMP switch to CLOSED
position (WP 0004), check if tank-to-pump valve operates to closed position.
If tank-to-pump valve does not operate to closed position, go to Step 11.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION