TM 9-2320-328-13&P-1
0075-9
DRAFT
0075
HWT0448
NOTE
Do not engage PUMP PTO during this procedure.
Valve operations can be checked
without water pump operation.
Valve motor operation can be checked either by noting vibration of valve assembly, or by
observing rotation of
7/16” hex at end of valve drive assembly worm gear shaft.
Step 8.
Push battery disconnect switch to on position (WP 0007).
While an assistant pushes
pump operator’s panel TANK FILL & RE-CIRCULATING LINE valve control OPEN and
CLOSE buttons (WP 0004), check if TANK FILL & RE-CIRCULATING LINE valve
control yellow THROTTLED indicator illuminates and tank fill & re-circulating line valve
motor operates.
If indicator illuminates and valve motor operates, replace tank fill &
re-circulating line valve drive assembly (WP 0248).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION


Back to Top