HWT0448
NOTE
•
Do not engage PUMP PTO during this procedure.
Valve operations can be checked
without water pump operation.
•
Valve motor operation can be checked either by noting vibration of valve assembly, or by
observing rotation of
7/16” hex at end of valve drive assembly worm gear shaft.
Step 8.
Push battery disconnect switch to on position (WP 0007).
While an assistant pushes
pump operator’s panel TANK FILL & RE-CIRCULATING LINE valve control OPEN and
CLOSE buttons (WP 0004), check if TANK FILL & RE-CIRCULATING LINE valve
control yellow THROTTLED indicator illuminates and tank fill & re-circulating line valve
motor operates.
If indicator illuminates and valve motor operates, replace tank fill &
re-circulating line valve drive assembly (WP 0248).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION