TM 9-2320-328-13&P-1
0075-6
DRAFT
0075
NOTE
Water tank must be drained.
Water will be released from water tank uncontrollably when
tank fill & re-circulating valve is removed.
Step 4.
Drain water tank if required (WP 0015).
Pull battery disconnect switch to off position
(WP 0007).
Reconnect valve control wire harnesses to original positions.
Remove tank
fill & re-circulating line valve (WP 0191) and inspect it for binding, damage, and
contamination.
a.
If tank fill & re-circulating line valve is free from binding, damage and
contamination, reinstall valve and replace tank fill & re-circulating line
valve motor and drive assembly (WP 0248), and go to Step 7.
b.
If tank fill & re-circulating line valve is binding, damaged, and/or
contaminated, repair (WP 0249), or replace tank fill & re-circulating line
valve (WP 0191).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION