TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 1173 of 1390

TM 9-2320-328-13&P-2
0299-5
DRAFT
0299
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
4.
Install pump house power distribution wire harness connector DP1 (14) on power distribution box (17) with
lockwasher (19) and nut (18).
5.
Install pump house power distribution wire harness connector DP2 (12) on power distribution box (17) with
lockwasher (16) and nut (15).
6.
Connect pump house wire harness connector (13) on pump house power distribution wire harness connector
DP1 (14).
7.
Connect pump house wire harness connector (11) on pump house power distribution wire harness connector
DP2 (12).
HWT2828


Back to Top