0300
INSTALLATION
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1.
Install primer pump control solenoid (4) on primer pump motor (3) with two screws (11).
2.
Install wire (10) on primer pump control solenoid (4) with locknut (9).
3.
Install jumperwire (8) on primer pump control solenoid (4) with locknut (7).
4.
Install wire 2774 (6) on primer pump control solenoid (4) with locknut (5).
5.
Install electrical strip (2) on primer pump motor (3) and primer pump control solenoid (4) with two locknuts (1).
END OF TASK
FOLLOW-ON MAINTENANCE
Install pump house panel G (WP 0339)
END OF TASK
END OF WORK PACKAGE
HWT2172