TM 9-2320-328-13&P-2
0168-1
DRAFT
0168
FIELD LEVEL MAINTENANCE
PRIMER VALVE CONTROL SOLENOID REPLACEMENT
INITIAL SETUP:
REMOVAL
NOTE
Tag and mark wires prior to removal to ensure proper installation.
1.
Remove nut (1) and wire 1640 (2) from stud (3).
2.
Remove nut (4) and wire 1590 (5) from stud (6).
3.
Remove nut (7) and wire 4065 (8) from stud (9).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
HWT2787A
Tools and Special Tools
Tool Kit, General Mechanic’s: Automotive
(WP 0398, Item 17)
Materials/Parts
Compound, Sealing (WP 0400, Item 10)
Tags, Identification (WP 0400, Item 23)
Lockwasher (2)
References
WP 0391, Fig. 17, 18
Equipment Conditions
Pump house panel K removed (WP 0339)