TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 506 of 1390

TM 9-2320-328-13&P-2
0167-2
DRAFT
0167
INSTALLATION
NOTE
Route cable in pump house as noted prior to removal.
Install cable ties as required.
1.
Position cable wire (1) on retainer (11).
2.
Install retainer (11) on lever (12) with washer (10) and screw (9).
Do not tighten screw.
NOTE
Install cable on bracket as noted prior to removal.
3.
Install cable (7) on bracket (8) with two cushion clips (6), screws (5), four washers (4), two lockwashers (3),
and nuts (2).
4.
Tighten screw (9).
5.
Bend cable wire (1).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Install pump house panel K (WP 0339)
2.
Install manual primer handle (WP 0164)
END OF TASK
END OF WORK PACKAGE
HWT2785