12. Install four washers (3), lockwashers (2), and screws (1) on dump chute (4) and water tank (5).
Do not tighten
screws.
NOTE
Tighten screws in a criss-cross pattern.
13. Tighten eight screws (7) and four screws (1) in a criss-cross pattern to 20 lb-ft (27.12 N•m).
END OF TASK
END OF WORK PACKAGE