TM 9-2320-328-13&P-2
0205-31/(32 blank)
DRAFT
0205
Change 1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
6.
Connect main wire harness connector (8) on chassis datalink Y connector (9).
7.
Connect main wire harness connector (6) on pressure governor control ECU datalink Y connector (7).
8.
Install cab 1-2-3 buzzer audio alarm (5) on cab instrument panel E (4) (WP 0203).
9.
Install cab 1-2-3 signal indicator (3) on cab instrument panel E (4) (WP 0201).
10. Install pressure governor control (2) (WP 0197).
11. Install bumper turret control (1) (WP 0375).
FOLLOW-ON MAINTENANCE
Connect batteries (TM 9-2320-325-14&P)
END OF TASK
END OF WORK PACKAGE