TM-9-2320-328-13-P-3

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 3 OF 3

MARCH 2009

  TM-9-2320-328-13-P-3 - Page 107 of 844

TM 9-2320-328-13&P-3
0339-27
DRAFT
0339
Change 1
PUMP HOUSE PANEL O REMOVAL
1.
Drain water tank (WP 0015).
2.
Remove hose (1) from fitting (2).
3.
Remove nine screws (3), lockwashers (4), and washers (5) from pump house panel O (6).
Discard
lockwashers.
4.
Remove five screws (7), lockwashers (8), washers (9), and pump house panel O (6) from vehicle.
Discard
lockwashers.
END OF TASK
PUMP HOUSE PANEL O INSTALLATION
1.
Install pump house panel O (6) on vehicle with five washers (9), lockwashers (8), and screws (7).
2.
Install pump house panel O (6) on vehicle with nine washers (5), lockwashers (4), and screws (3).
3.
Install hose (1) on fitting (2).
END OF TASK
HWT2781