TM 9-2320-328-13&P-3
0340-8
DRAFT
0340
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
NOTE
•
Tag and mark drain lines and hoses prior to removal to ensure proper installation.
•
Cap and plug drain lines and hoses upon removal.
23. Loosen jam nut (48) and remove hydraulic drain line (49) from mounting bracket (50).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
24. Disconnect main wire harness connector (51) from pump house wire harness connector (52).
25. Disconnect main wire harness connector (53) from pump house wire harness connector (54).
HWT2297A
HWT2970