TM-9-2320-328-13-P-3

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 3 OF 3

MARCH 2009

  TM-9-2320-328-13-P-3 - Page 120 of 844

TM 9-2320-328-13&P-3
0340-12
DRAFT
0340
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Pump house assembly is VERY heavy.
Do not attempt to lift or move pump house
assembly without the aid of three assistants and a suitable lifting device. Use
extreme caution when lifting or moving pump house assembly.
Failure to comply
may result in damage to equipment and/or death or injury to personnel.
CAUTION
Care must be taken when removing hoses and wires from pump operator’s panel
housing and through pump house panel N.
Failure to comply may cause damage to
equipment.
NOTE
Note position and remove split loom, cushion clips, and cable ties as required.
Note routing of wires and hoses prior to removal to ensure proper installation.
36. With the aid of three assistants, attach a suitable lifting device to three lift points (85) on pump house
frame (84) and carefully remove pump house assembly (86) from vehicle.
HWT2304A
WARNING
ICON 8,9,10,11


Back to Top