TM-9-2320-361-20

2-1/2-TON, 6x6, M44A2 SERIES TRUCKS (MULTIFUEL)

TECHNICAL MANUAL; UNIT MAINTENANCE

OCTOBER 1991

  TM-9-2320-361-20 - Page 328 of 1207

TM 9-2320-361-20
3-16. AIR CLEANER INDICATOR AND TUBE MAINTENANCE
This task covers:
a. Testing
c. Inspection and Cleaning
b. Removal
d. Installation
INITIAL SETUP:
APPLICABLE MODELS
All
MATERIALS/PARTS
Antiseize tape (Appendix C, Item 27)
PERSONNEL REQUIRED
Two
REFERENCES (TM)
TM 9-2320-361-10
TM 9-2320-361-20P
EQUIPMENT CONDITION
Parking brake set (TM 9-2320-361-10).
Hood raised and secured (TM 9-2320-361-10).
GENERAL SAFETY INSTRUCTIONS
Compressed air source will not exceed 30 psi
(207 kPa).
Eyeshields must be worn when cleaning with
compressed air.
a. Testing
1. Loosen clamp (6) and remove cap (7) and clamp (6) from air cleaner (5).
2. Start engine (TM 9-2320-361-10) and run at 1200 rpm.
3. Using piece of cardboard (4), cover approximately 90% of air cleaner assembly (5) opening.
4. Observe air cleaner indicator (2) to see if red band (3) is visible. If red band is visible, indicator
works properly. If not, air cleaner indicator (2) is defective or tube (1) is obstructed. Stop engine
(TM 9-2320-361-10).
5. Remove cardboard (4) and install cap (7) on air cleaner (5) with clamp (6).
3-25