para. 11-22
TM 9-2320-361-20
6-5. TRANSFER CASE BREATHER MAINTENANCE
This task covers:
a. Removal
c. Installation
b. Cleaning
INITIAL SETUP:
APPLICABLE MODELS
EQUIPMENT CONDITION
All
Parking brake set (TM 9-2320-361-10).
MATERIALS/PARTS
Cab tunnels removed (para. 11-22).
Rag (Appendix C, Item 21)
GENERAL SAFETY INSTRUCTIONS
Drycleaning solvent (Appendix C, Item 26)
Keep fire extinguisher nearby when using
REFERENCES (TM)
drycleaning solvent.
TM 9-2320-361-10
TM 9-2320-361-20P
1. Wipe area around transfer case breather (2) with rag.
2. Remove transfer case breather (2) from transfer case (1).
WARNING
Drycleaning solvent is flammable and will not be used near open
flame. Use only in well-ventilated places. Failure to do so may
result in injury to personnel.
Clean transfer case breather (2) with cleaning solvent.
6-20