TM-9-2320-366-20-1

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 1 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-1 - Page 1336 of 1824

TM 9-2320-366-20-1
e63.
STOPLIGHTS AND BLACKOUT STOPLIGHTS DO NOT OPERATE
INITIAL SETUP
Equipment Condition
Engine shut down (TM 9-2320-366-10-1).
Personnel Required
(2)
Tools and Special Tools
Tool Kit, Genl Mech (Item 46, Appendix C)
STE/ICE-R (Item 41, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
References
TM 9-4910-571-12&P
2-772
START
Is 12 vdc present on relay
K6 terminal 86?
1.
WARNING
Read WARNING
on following page.
KNOWN INFO
Brakes operate.
Engine starts.
Circuit breaker OK.
POSSIBLE PROBLEMS
Faulty dashboard cable
assembly.
Faulty relay K6.
Faulty stoplight switches.
TEST OPTIONS
Voltage Test or
STE/ICE-R Test #89
REASON FOR QUESTION
This question eliminates
possible problems and
determines where
troubleshooting continues.
NO
YES
Go to step 7 of this fault.


Back to Top