2-958.7
(1) Set multimeter to ohms.
(2) Connect positive (+) probe of multimeter to
pressure transducer connector pin C.
(3) Connect negative (-) probe of multimeter to
pressure transducer connector pin A and
note reading on multimeter.
(4) If 1-50 ohms resistance is not present,
replace pressure transducer (para 12-7).
RESISTANCE TEST


Back to Top