TM-9-2320-366-20-3

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 3 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-3 - Page 371 of 1396

TM 9-2320-366-20-3
VOLTAGE TEST
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle.
Jewelry can catch on equipment and
cause injury or short across electrical circuits
and cause severe burns or electrical shock.
WARNING
(1) Remove wing screw from power
distribution shelf.
(2) Loosen wing screw on electrical
distribution block cover.
(3) Remove electrical distribution block cover
from power distribution shelf.
(4) Set multimeter to volts DC.
(5) Connect positive (+) probe of multimeter to
terminal lug TL3.
(6) Connect negative (-) probe of multimeter to
known good ground and note reading on
multimeter.
(7) If 24 VDC is not present, go to step 2 of
this fault.
(8) If 24 VDC is present, contact supervisor,
Driver Visual Enhancement (DVE)
troubleshooting needs to be performed.
Change 2
2-2297