2-2294
Change 2
TEST OPTIONS
YES
NO
TEST OPTIONS
2.
Continuity Test or
STE/ICE-R Test #91
Replace circuit breaker CB7
(para 20-80).
Perform Special Purpose Kit
Troubleshooting task x1. No Power
to Digitization Rack.
REASON FOR QUESTION
Is continuity present through
circuit breaker CB7?
If continuity is not present,
circuit breaker CB7 is faulty.
If continuity is present,
perform Special Purpose Kits
Troubleshooting task x1. No
Power to Digitization Rack.
TM 9-2320-366-20-3
x4. NO POWER TO PRECISION LIGHTWEIGHT GLOBAL POSITIONING SYSTEM RECEIVER
(PLGR) (CONT)
Circuit breaker CB7 is not
tripped.
POSSIBLE PROBLEMS
Faulty circuit breaker CB7.
Faulty digitization rack power
supply.