TM-9-2320-366-20-3

M1083 SERIES, 5 TON, 6x6, MEDIUM TACTICAL VEHICLES (MTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 3 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-366-20-3 - Page 366 of 1396

1.
WARNING
Read WARNING
on following page.
TEST OPTIONS
Voltage Test or
STE/ICE-R Test #89
YES
NO
TEST OPTIONS
REASON FOR QUESTION
Go to step 2 of this fault.
2-2292
Change 2
START
TM 9-2320-366-20-3
Circuit breaker CB7 is not
tripped.
POSSIBLE PROBLEMS
Faulty circuit breaker CB7.
Faulty digitization rack power
supply.
Faulty Precision Lightweight
Global Positioning System
Receiver (PLGR).
Is 24 VDC present at
terminal lug TL9?
If 24 VDC is not present, go to
step 2 of this fault.
If 24 VDC
is present, perform Precision
Lightweight Global
Positioning System Receiver
(PLGR) troubleshooting.
Contact supervisor, Precision Lightweight Global
Positioning System Receiver (PLGR) troubleshooting
needs to be performed.
INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-366-10-2)
Materials/Parts
Ties, Cable, Plastic (Item 69, Appendix D)
Tools/Special Tools
Multimeter, Digital (Item 22, Appendix C)
Tool Kit, Genl Mech (Item 46, Appendix C)
Personnel Required
(2)
x4. NO POWER TO PRECISION LIGHTWEIGHT GLOBAL POSITIONING SYSTEM RECEIVER
(PLGR)


Back to Top